電解鹽次氯酸鈉發生器-醫院污水消毒設備 醫院采用次氯酸鈉消毒具有下列優點:次氯酸鈉發生器電解原料食(shi)用(yong)鹽,便宜,易于采購;現(xian)場制備(bei)的次氯酸鈉溶液(ye)還可通過(guo)加水稀(xi)釋后做(zuo)成其他用(yong)途的消毒劑。
電解鹽次氯酸鈉發生器-醫院污水消毒設備?
次(ci)氯(lv)酸鈉發生器的管理和(he)維護(hu)知(zhi)識。1. 發電(dian)(dian)(dian)(dian)機應(ying)(ying)(ying)由專門人員管理,熟悉(xi)各(ge)部件的性能和(he)使用(yong)(yong),并(bing)定期維護(hu)。2. 鹽(yan)水配(pei)制應(ying)(ying)(ying)準確;3. 保(bao)護(hu)電(dian)(dian)(dian)(dian)極(ji)(ji)(ji);(1) 清潔電(dian)(dian)(dian)(dian)極(ji)(ji)(ji)板(ban):原(yuan)水的硬度會(hui)影響(xiang)電(dian)(dian)(dian)(dian)極(ji)(ji)(ji)板(ban)的結(jie)垢(gou)。當(dang)極(ji)(ji)(ji)板(ban)結(jie)垢(gou)時(shi),槽(cao)電(dian)(dian)(dian)(dian)壓升高,電(dian)(dian)(dian)(dian)流(liu)明顯(xian)下(xia)(xia)降,影響(xiang)輸(shu)出(chu),增(zeng)加(jia)功(gong)耗。(2) 發現(xian)極(ji)(ji)(ji)板(ban)鈍化(hua):如(ru)果(guo)表面涂(tu)層損壞,電(dian)(dian)(dian)(dian)池(chi)電(dian)(dian)(dian)(dian)壓升高,電(dian)(dian)(dian)(dian)流(liu)明顯(xian)下(xia)(xia)降,應(ying)(ying)(ying)更換新(xin)的極(ji)(ji)(ji)板(ban)。(3) 定期擦拭(shi)陰極(ji)(ji)(ji)和(he)陽極(ji)(ji)(ji)的接線片和(he)螺釘,必要時(shi)定期更換和(he)維護(hu),防止過(guo)度銹蝕(shi)影響(xiang)設備運(yun)行。(4) 運(yun)行電(dian)(dian)(dian)(dian)流(liu)和(he)電(dian)(dian)(dian)(dian)壓不(bu)得(de)超過(guo)發電(dian)(dian)(dian)(dian)機規定的電(dian)(dian)(dian)(dian)流(liu),外部電(dian)(dian)(dian)(dian)壓應(ying)(ying)(ying)影響(xiang)運(yun)行電(dian)(dian)(dian)(dian)流(liu)。應(ying)(ying)(ying)注意在(zai)(zai)安全范圍內的調整(zheng)和(he)使用(yong)(yong)。(5) 保(bao)持(chi)鹽(yan)水箱清潔。鹽(yan)須(xu)干凈無雜質(zhi)。如(ru)果(guo)使用(yong)(yong)原(yuan)鹽(yan),須(xu)添加(jia)過(guo)濾器。4.次(ci)氯(lv)酸鈉溶液不(bu)容(rong)易長時(shi)間儲存。它應(ying)(ying)(ying)該在(zai)(zai)夏(xia)天生產,當(dang)天用(yong)(yong)完。冬季貯存時(shi)間不(bu)應(ying)(ying)(ying)超過(guo)一周,并(bing)應(ying)(ying)(ying)避(bi)光(guang)貯存。(如(ru)果(guo)溫度低于25℃,每天將損失0.1-0.15毫(hao)克(ke)/升有(you)效氯(lv),如(ru)果(guo)溫度超過(guo)30℃,每天將損失0.3-0.7毫(hao)克(ke)/升有(you)效氯(lv))。
電解鹽次氯酸鈉發生器-醫院污水消毒設備?水(shui)廠(chang)、污水(shui)處(chu)理(li)廠(chang)、醫院(yuan)和其他工(gong)(gong)(gong)業領域都會產(chan)生(sheng)大(da)量(liang)的(de)(de)廢水(shui)。根(gen)據環境保護的(de)(de)要求,這(zhe)些廢水(shui)須經過(guo)處(chu)理(li)才能(neng)排(pai)放。如(ru)果一(yi)個工(gong)(gong)(gong)人(ren)想把工(gong)(gong)(gong)作做好,他須首先磨利(li)他的(de)(de)工(gong)(gong)(gong)具(ju)(ju)。因此(ci)(ci),設備(bei)的(de)(de)選(xuan)擇非常重要。次氯(lv)酸鈉(na)發(fa)生(sheng)器是(shi)(shi)(shi)一(yi)種新型水(shui)處(chu)理(li)設備(bei),具(ju)(ju)有產(chan)量(liang)高、能(neng)耗低(di)、運(yun)行(xing)成本(ben)低(di)等特點(dian)。電解(jie)(jie)法次氯(lv)酸鈉(na)發(fa)生(sheng)器所運(yun)用(yong)的(de)(de)質料是(shi)(shi)(shi)食(shi)鹽(yan)(yan)(yan)(yan)和電,食(shi)鹽(yan)(yan)(yan)(yan)一(yi)般情況下運(yun)用(yong)咱們常用(yong)的(de)(de)食(shi)用(yong)鹽(yan)(yan)(yan)(yan),但(dan)許多(duo)客戶(hu)對食(shi)用(yong)鹽(yan)(yan)(yan)(yan)能(neng)否用(yong)工(gong)(gong)(gong)業鹽(yan)(yan)(yan)(yan)代替存在疑問。關于這(zhe)個問題是(shi)(shi)(shi),答(da)案是(shi)(shi)(shi)非常顯著的(de)(de)——不能(neng)夠。這(zhe)是(shi)(shi)(shi)由于食(shi)用(yong)鹽(yan)(yan)(yan)(yan)和部(bu)分工(gong)(gong)(gong)業鹽(yan)(yan)(yan)(yan)指的(de)(de)是(shi)(shi)(shi)氯(lv)化鈉(na),次氯(lv)酸鈉(na)發(fa)生(sheng)器在電解(jie)(jie)過(guo)程(cheng)中(zhong)點(dian)解(jie)(jie)的(de)(de)是(shi)(shi)(shi)氯(lv)化鈉(na),因而許多(duo)人(ren)以為能(neng)夠彼此(ci)(ci)運(yun)用(yong)。可是(shi)(shi)(shi),在還有一(yi)類工(gong)(gong)(gong)業鹽(yan)(yan)(yan)(yan)被成為,這(zhe)也是(shi)(shi)(shi)鹽(yan)(yan)(yan)(yan)的(de)(de)一(yi)種,可是(shi)(shi)(shi)兩者之間存在很(hen)大(da)的(de)(de)區別,所以客戶(hu)在運(yun)用(yong)時較好清晰所電解(jie)(jie)的(de)(de)氯(lv)化鈉(na),而不是(shi)(shi)(shi)的(de)(de)工(gong)(gong)(gong)業鹽(yan)(yan)(yan)(yan)。
地址:濰坊市奎文區藍翔街機場路東北角 動力智谷西區 © 山東和創智云環保裝備有限公司 All rights reserved. 技術支持:環保在線 GoogleSitemap